Strip-fin plate-fin, surface 1/8-20.06(D)
Procedure Compact_HX_ND('sf_plate-fin_s18-2006D', Re: f,j_H) is a non-dimensional procedure that returns the friction factor and the Colburn j factor for external flow through strip-fin plate-fins with surface 1/8-20.06(D) given the Reynolds number. The values calculated are based on a best fit curve to experimental data. These data are from Kays and London (1984) p. 255.
Related procedures include:
Geometry-(more info)
CHX_geom_plate_fin('sf_plate-fin_s18-2006D', a, b_2: b_1, D_o, fin_pitch, D_h, fin_thk, sigma, alpha, A_fin\A)
Coefficient of heat transfer-(more info)
CHX_h_plate_fin('sf_plate-fin_s18-2006D', a, b_2, m_dot, A_fr, Fluid$,T, P:h)
Pressure drop-(more info)
CHX_DELTAp_plate_fin('sf_plate-fin_s18-2006D', a, b_2, m_dot, A_fr, L, Fluid$, T_i, T_o, P: DELTAp)
Additional Information
Fin pitch = 790 per m
Plate spacing, b = 5.11e-3 m
Splitter length flow direction = 3.175e-3 m
D_h = 1.491e-3 m
Fin metal (aluminum) thickness = 0.102e-3 m
Splitter metal thickness = 0.152e-3 m
Total heat transfer area/volume between plates(Beta) = 2290 m^2/m^3
Fin area (including splitter)/total area = 0.843