Contents - Index


Strip-fin plate-fin, surface 1/8-16.12(T)

 

 

Procedure Compact_HX_ND('sf_plate-fin_s18-1612T', Re: f,j_H) is a non-dimensional procedure that returns the friction factor and the Colburn j factor for external flow through strip-fin plate-fins with surface 1/8-16.12(T) given the Reynolds number. The values calculated are based on a best fit curve to experimental data. These data are from Kays and London (1984) p. 256.   

 

Related procedures include:

Geometry-(more info)

CHX_geom_plate_fin('sf_plate-fin_s18-1612T', a, b_2: b_1, D_o, fin_pitch, D_h, fin_thk, sigma, alpha, A_fin\A)

Coefficient of heat transfer-(more info)

CHX_h_plate_fin('sf_plate-fin_s18-1612T', a, b_2, m_dot, A_fr, Fluid$,T, P:h)

Pressure drop-(more info)

CHX_DELTAp_plate_fin('sf_plate-fin_s18-1612T', a, b_2, m_dot, A_fr, L, Fluid$, T_i, T_o, P: DELTAp)

 

Additional Information

Fin pitch = 635 per m

Plate spacing, b = 7.98e-3 m

Splitters evenly spaced

Fin length flow direction = 3.175e-3 m

D_h = 1.567e-3 m

Fin metal (aluminum) thickness = 0.152e-3 m

Splitter metal thickness = 0.152e-3 m

Total heat transfer area/volume between plates(Beta) = 2133 m^2/m^3

Fin area (including splitter)/total area = 0.882

 

 