Cylinder_Q_ND
Function cylinder_Q_ND(Fo, Bi) returns the non-dimensional heat transfer within a long circular cylinder with the outside edge exposed to convection (r=r_o). The supplied values, Fo, Bi represent the Fourier number and Biot number respectively. A separation of variable technique is used as described in Section 3.5.2 of Nellis and Klein.
Inputs:
Output:
Example:
Fo=0.23
Bi=1.02
Q_hat=cylinder_Q_ND(Fo, Bi)
{Solution: Q_hat=0.319}