Contents


Impinging_Jets_SSN

 

 

Procedure Impinging_Jets_SSN(Fluid$, T, P, u, B, H, x : h_bar, Nusselt, Re) calculates the average heat transfer and Nusselt number for a single slot nozzle (SSN) jet with slot width B positioned perpendicular to a plate with its exit a distance H from the plate.  The heat transfer coefficient is averaged over an area of the plate with distance x from the nozzel center.

 

Inputs

Fluid$ is a string or string variable that can be any fluid in the EES data base.  The fluid can be an ideal gas, a real fluid, a brine, or an incompressible fluid in the Solid-Liquid_Props fluids library.  

T - the temperature of fluid exiting the jet  [C], [K], [F], or [R].  

P -  pressure can be in [Pa], [kPa], [bar], [MPa], [atm] or [psia].    (Note that for brines, this parameter provides the concentration in % instead of pressure.)  

u  - the velocity of the flow exiting the nozzle [m/s] or [ft/min]

B -  the width of the slot in [m] or [ft]

H -  the distance between the nozzle exit and the surface that the jet impinging on in [m] or [ft]

x - the position on the surface measured from the nozzle center that the average heat transfer coefficient is applied in [m] or [ft]

 

Outputs

h_bar -  average heat transfer coefficient in [W/m^2-K] or [Btu/hr-ft^2-R]

Nusselt - average Nusselt number [-]

Re - Reynolds number [-]

 

Notes:

This procedure is responsible for determining the property data of the fluid specified and calculating the Reynold and Prandtl numbers. This procedure then passes dimensionless information  to the non-dimensional procedure Impinging_Jets_SSN_ND. The non-dimensional procedure returns the values for  Nusselt.   Impinging_Jets_SRN calculates t the heat transfer coefficient 

 

Example

$UnitSystem SI C kPa J mass

Fluid$='air'

T=25 [C]

P=100 [kPa]

Vel=20 [m/s]

B=0.005 [m]

x=0.025 [m]

H=0.04 [m]

Call impinging_jet_ssn(Fluid$, T, P, Vel, B, H, x:h_bar, Nusselt, Re)

 

{Solution

h_bar=138.6 [W/m^2-K]

Nusselt=54.35 

Re=12641 

}

 

Impinging Jets Index